Professional chimney service

Fireplace Repair in Laguna Niguel for Masonry and Factory Units

Tell Us the Symptom

Millivolts Read First
Written Price Before Work
Photos With Every Report
Maker-Listed Parts
CO Reading After Service
Based in Laguna Niguel
Millivolts Read First
Written Price Before Work
Photos With Every Report
Maker-Listed Parts
CO Reading After Service
Based in Laguna Niguel

What the Visit Covers

Heat is hard on a firebox. We reset loose firebrick in refractory mortar, swap cracked panels in factory units for the maker's own, and repair or replace the damper. Glass doors get new gaskets or new glass. When a gas set lives in the firebox, we lift it out, protect it during the work and return it to its layout chart, then light it and watch the flame.

Loose firebrick reset in refractory mortar
Factory panels ordered by model number
Damper freed, rebuilt or replaced
Door gaskets and glass renewed
Gas set lifted out, stored and relit afterwards

Getting a Firebox Ready for Its Next Life

A good number of the repair calls we take start with a plan for gas. Someone in Laguna Niguel has decided to stop burning wood, the installer has looked at the firebox, and the answer was that it needs work first. On a masonry fireplace that usually means firebrick: bricks cracked through, loose in their joints, or missing at the back wall where years of logs were tossed in. We cut out the damaged ones and set new firebrick in refractory mortar, the kind made for the heat, so the wall is tight and flat. The smoke chamber above the damper gets the same scrutiny, since rough or gapped masonry there can trap exhaust and later let heat reach the framing. On a factory-built fireplace, the box is lined with refractory panels that crack and crumble with age, and the only correct replacements are the panels listed for that model, ordered by its maker and model number.

Dampers are the other common item. A cast-iron damper that has rusted in place, a handle that spins without moving the plate, or a frame that has broken all cause trouble whether the fire is wood or gas. If a vented gas log set is going in, the damper also needs a clamp or stop that holds it partly open at all times, because those logs send their exhaust straight up the flue. We free or replace the throat damper, or, on chimneys where the old frame is beyond saving, move the seal up to the crown with a damper that closes under the cap. Each repair is listed on paper with the material named, so you know what went into your fireplace and why. A firebox that has been put right also lasts longer under the new burner.

Repair or Replace the Unit Itself

Factory-built fireplaces from the decades when many houses in Mission Viejo and Laguna Niguel went up are now reaching the age when the owner has to decide between repairing the box and replacing it. If the panels are cracked but the metal shell is sound and parts for the model still exist, repair makes sense. If the shell has rusted through, the model was discontinued long ago, or the unit has no listing label left at all, sinking money into it rarely does. In those cases we explain the options: a gas insert that fits inside a masonry opening, or the removal of the old factory unit and its replacement with a new listed one. We will not install substitute parts on a listed unit to keep it going, because that voids the listing it was approved under.

To start, tell us whether the fireplace is brick or metal, what burns in it now, and what has gone wrong: smoke in the room, loose brick, a damper that will not move, panels you can see are cracked. If a conversion to gas is the reason you are calling, say so, because the repair list changes with the appliance that will sit in the box. The office sets a visit, and the visit produces a written list and price before anything is started. Nothing gets started until you have agreed to the list in writing. If the repair list is long enough that an insert would cost less in the end, we point that out with both figures side by side, and the decision stays yours. Some owners repair now and convert later; that works too, as long as the firebox repairs suit the future appliance.

The Kerrigan Order of Work

Read First

A meter or camera points to the part before we name it

Maker's Parts

Replacements ordered by model number from the maker's list

Price on Paper

Published prices where we have them, a written figure otherwise

Test Burn

A full burn and a carbon monoxide reading before we leave

More Kerrigan Services

Chimney Sweep

Soot and glaze lifted off the flue walls, the smoke shelf emptied, and a short note on what came out and why.

Learn More →

Chimney Inspection

A flue in steady use gets the Level 1 check; a house where something has changed gets the Level 2 camera survey.

Learn More →

Chimney Repair

Mortar, tile, crown and roof metal fixed at the part that failed, with the price set down on paper before work begins.

Learn More →

Fireplace Inspection

The room side of the hearth: firebox walls, glass, damper, hearth reach and how close the mantel sits to the opening.

Learn More →

Chimney Level 2 Inspection

Video of each flue plus the attic and crawl space, booked when the house sells, the fuel changes or the ground shakes.

Learn More →

Chimney Cap Installation

Stainless or copper tops fitted over each flue, with ember mesh on wood flues and the maker's listed top on gas vents.

Learn More →

Chimney Flashing Repair

Rusted or lifted metal at the roof line replaced in the right overlap, so rain runs over each seam rather than into it.

Learn More →

Chimney Masonry Repair

Soft joints repointed, flaking brick swapped out and cracks read for movement, with a mortar picked to suit the brick.

Learn More →

Chimney Rebuilds

Stacks taken down to firm brick and built back with steel, ties to the house framing, a new crown, a cap and a liner.

Learn More →

Fireplace Cleaning

Ash, soot and glass cleaned from the room side, then a small test fire to see whether smoke stays in the flue.

Learn More →

Gas Fireplace Cleaning

On a gas unit we clean burner ports, pilot hood, ember bed and glass, then check the flame and read for carbon monoxide.

Learn More →

Gas Fireplace Repair

Pilots that drop out, igniters that spark with no flame and valves that stay shut, traced with a meter before a part is ordered.

Learn More →

Fireplace Remodel

New faces, mantels and hearths planned around the clearances a gas or wood unit needs, measured before you pick stone or tile.

Learn More →

Fireplace Inserts

Gas and wood inserts set into a sound firebox, with a full-height liner, a gas supply where needed and the permit filed.

Learn More →

Pellet Stove Repair

Pellet stoves that jam, fail to catch or quit mid burn, traced through the board codes and fixed with the maker's parts.

Learn More →

Wood Stove Repair

Door rope, baffle, firebrick and combustor renewed on wood stoves, and the clearances on the label measured against the room.

Learn More →

Gas Logs

Vented log sets picked for your opening, fitted on a clean flue, with burner and logs laid out the way the maker shows.

Learn More →

Chimney Seismic Retrofit

Steel bracing, straps or a lighter rebuilt top for brick chimneys, chosen after a look at how sound the masonry is.

Learn More →

Chimney Crown Repair

Cracked or flat crowns sealed, or poured new so water sheds off the edge and the flue tile is free to move.

Learn More →

Dryer Vent Cleaning

Lint cleared from the dryer duct end to end, the outside flap freed, and airflow measured before and after.

Learn More →

Chimney Liner Installation

Stainless liners sized to the appliance and run the full flue height, for gas inserts, wood stoves or a cracked clay flue.

Learn More →

Chimney Leak Repair

Water at the chimney traced to where it enters, whether flashing, crown, brick face or an open flue, and fixed at that point.

Learn More →

Chimney Waterproofing

A breathable repellent on sound brick, put on after the repairs are done, so the face sheds winter rain.

Learn More →

Chimney Damper Repair

Rusted, bent or stuck throat dampers freed or replaced, or a sealing top damper fitted on the crown with a cable to the firebox.

Learn More →

Chimney Chase Cover

Rusted or sagging metal tops on framed chimneys replaced with stainless made to measure, sloped so water runs off.

Learn More →
Book a Gas Hearth Visit